Electrical Rule Check (ERC)
Part I . ERC verification.
- The ERC verification can only be performed on an extracted view . To learn how to create an extracted view click here.
- Once you have your extracted view open
click Verify =>ERC.... This will bring up the
ERC window.
-
Make sure that in the Rules File field divaERC.rul is entered.
- Uncheck the Rules Library box.
- Click Run. Cadence will run the ERC.
You should be able to see in the CIW window
that the check was started. Once the analysis is completed an Analysis
job Succeeded Window will appear informing you if the ERC was
successfully performed.
- Click OK to close this dialogue box.
To see the errors on the extracted view
click Display Errors in the
ERC window. The errors will appear highlighted in blue on the extracted
view. To remove the blue highlighting press Remove
all errors in the ERC window.
- To get an explanation of each individual error is from the ERC
window click Explain Error, and then
click on an error in the extracted view.
The explanation will appear in the CIW
window. To have the errors explained in a separate window first click on
text window in the bottom center of the ERC
window. Then Click Explain Error and
finally click on an error in the extracted view..
Updated March 3, 2000 by Kai He at khe@ece.cmu.edu